Skip to content

Cart

Your cart is empty

Sleep apnea

Cleaning your CPAP machine and mask: a component-by-component routine

The principle: identify the component before choosing the method. Clean washable parts according to their instructions; disposable filters and HumidX must not be washed. An effective routine combines cleaning, drying, checking condition and replacing parts when required.

White disposable filters for a ResMed AirSense 11 device.

Photograph of the product shown in the catalogue.

Everyday equipment care

Good equipment care does not require a collection of products. It mainly requires recognising different materials, allowing time to dry and knowing when a component needs replacing. This method helps you build a reliable routine with your care provider, suited to your actual equipment.

Start with an equipment identity sheet

Record the CPAP model, full mask name, cushion material, tubing reference and water chamber reference. Keep instructions accessible on paper or in an offline folder. Two components from the same manufacturer may require different care.

Cleaning, disinfection and replacement: these are different operations. Cleaning removes dirt using the specified method. Any disinfection requires a dedicated procedure. Replacement is for a worn, damaged or time-expired part; additional cleaning does not restore its properties.

Ask your care provider to distinguish your home routine from work that requires their intervention. A procedure for reprocessing equipment between patients should not be applied independently to your personal equipment.

A component matrix to keep with your equipment

Which care method for which component?
ComponentMethod to confirm in its instructionsImportant detail
Silicone cushionDisassemble, wash gently with approved products, rinse and dry.Avoid residue and check the seal after reassembly.
AirTouch F20 foam cushionDo not immerse or rinse; wipe the exterior if needed according to the instructions, using a compatible alcohol-free wipe.Do not apply this rule to the entire AirTouch range, which uses different materials.
Headgear and frameUse the mask-specific method and schedule.Do not stretch, wring or heat to speed up drying.
TubingWash and rinse as instructed; dry away from sunlight and heat.Do not immerse the power supply; observe precautions for heated connectors.
Water chamberEmpty and clean according to the exact model.Dishwasher use, temperature and descaling must be authorised in its instructions.
Disposable filterInspect and replace as instructed.Do not wash disposable AirSense 11 or AirMini filters.
HumidXReplace within 30 days of opening, or sooner if needed.Do not wash or immerse; remove before washing neighbouring parts.
CPAP housingUnplug, then clean the exterior as instructed; use a dry cloth for AirSense 11 and AirMini.Do not open, immerse or spray products into openings.

Put the frequencies specified in your instructions into your diary: separate after-use tasks, periodic cleaning and consumable deadlines. A schedule for another model does not replace the one for yours.

Follow a simple sequence without mixing up components

  1. Wash your hands and prepare a clean surface. Stop and unplug the machine; allow heated components to cool.
  2. Disassemble only the parts intended for user maintenance. Set non-washable consumables aside.
  3. Clean permitted components using the water and product specified in their instructions.
  4. Rinse thoroughly where rinsing is required, then dry in a clean place away from direct sunlight and heat.
  5. Inspect, reassemble and check that connections are properly inserted before use.

Allow enough time to avoid putting wet parts back together at bedtime. A small dedicated drying area reduces handling and contact with household cleaning products. Do not force a component that resists: return to the assembly diagram.

Treat the cushion according to its material, not its brand name

The cushion makes contact with your face. Skin deposits and residues can complicate care or sealing, but scrubbing harder does not necessarily improve the result. Follow the intended disassembly method and handle thin areas gently.

AirTouch F20 foam is a distinct case: its instructions prohibit rinsing and immersion. If it has been immersed or becomes excessively dirty, replace it according to those instructions. Do not extend this prohibition to every cushion named AirTouch: some use other materials.

A practical reminder: write “silicone cushion”, “F20 foam” or the exact material on your equipment sheet. That small detail can prevent a well-meaning relative from washing every component the same way.

Keep an eye on tubing and the water chamber

Inspect tubing ends, bending points and water chamber seals. A crack, deformation or damaged seal needs checking and often replacement. Persistent leaks should not be repaired with adhesive tape, glue or sealant.

Do not transfer a descaling recipe from one device to another. Whether a chamber can go in the dishwasher depends on its version and instructions. The type of water to use also needs confirming for your model and country.

To identify a chamber sold in the shop, compare the HumidAir for AirSense 10 and HumidAir for AirSense 11 product pages. Similar names do not make them interchangeable.

Avoid unnecessary products and false shortcuts

Do not use bleach, alcohol, essential oils, perfume or household cleaner on a component unless its instructions explicitly permit it. A pleasant smell is not evidence that a product is compatible with respiratory equipment.

Ozone or UV devices must not replace the recommended cleaning process. The FDA explains that specialised cleaning machines are not necessary for the usual routine and that add-on devices do not replace it. Compatibility must be established for each component; the term “activated oxygen” does not constitute manufacturer approval.

Before buying from the care and hygiene collection, check the intended use, materials covered and whether rinsing is needed. Our cleaning FAQ provides additional guidance.

Know when to request a check

After reassembly, persistent odour, a new leak or an unusual sound should prompt inspection of components and connections as instructed. If the housing is wet or damaged, or the machine behaves abnormally, stop using it and contact the professional responsible for your equipment.

To help with support, note the model, affected component, product used and when the problem appeared. A photograph of the part, without unnecessary personal medical information, can help distinguish incomplete assembly from damage. Do not alter pressure to compensate.

Questions you may still have

Can I rinse a disposable filter to make it last longer?

No. Disposable AirSense 11 and AirMini filters are not designed for washing. A filter that looks clean after rinsing has not recovered its original characteristics. Replace it according to its instructions and condition; for another model, first establish whether the filter is washable or disposable.

Do all parts have to dry until the evening?

The criterion is the drying required by the instructions, not a fixed time of day. Cleaning early provides useful flexibility. Do not speed things up with a hairdryer, radiator or sunlight. If a component does not dry normally, check the method with your care provider rather than improvising.

Must I buy a whole new mask if one part is worn?

Not necessarily. A compatible spare part may be available, but selection depends on the model and condition of the whole mask. Have the part requiring replacement identified. A new cushion cannot correct stretched headgear or a damaged frame.

A useful next step

Create a four-column sheet: component, care method, deadline in its instructions and signs of wear to watch for. Have your care provider confirm it and keep it near the equipment. A short, repeatable routine is more useful than a complicated protocol that becomes difficult to maintain.

Sources and references

References checked on 23 November 2026.

  1. Nettoyage de la PPC et des accessoires — ResMed
  2. Remplacement des composants et matériaux de bulles — ResMed
  3. Notice AirSense 11 Europe : nettoyage, filtres et inspection — ResMed
  4. Notice AirFit F20 et AirTouch F20 : silicone et mousse — ResMed
  5. Notice AirMini : filtres, composants et HumidX — ResMed
  6. Dispositifs de nettoyage CPAP : rôle et limites — U.S. Food and Drug Administration

Written by PlanèteSommeil. This guide provides information and helps you prepare discussions with your care team; it does not replace an individual assessment.

Author

PlanèteSommeil

This document provides general information. It is not a substitute for a personalized medical consultation, diagnosis, or follow-up.

All health records

A question before choosing?

Find selection criteria, compatibility details and practical advice in our FAQ.

Masks, CPAP and accessories

Assess your sleep