Masks, CPAP and accessories
Choose the right components, improve comfort and care for your equipment in line with the manufacturer’s instructions.
The essentials to guide you, details to help you understand, and useful links for your next step.
Choosing your mask
Nasal, nasal pillows or full face mask: what are the differences when choosing?
Key takeaway
Start with a contact area suited to your breathing and treatment: around the nose, at the nostrils, or around both nose and mouth. Check comfort in your usual sleeping position.
More detail
A nasal mask rests around or beneath the nose, depending on the model. A nasal pillows mask uses small cushions at the entrance to the nostrils. A full face mask, also called an oronasal mask, covers the mouth and nose, sometimes with a cushion positioned beneath the nostrils.
The choice depends on nasal breathing, possible mouth leaks, facial shape and comfort. The most discreet model is not necessarily the best suited to your treatment. Before ordering, compare the contact area, tubing connection, available sizes and precautions in the instructions. A fitting with professional support remains useful when changing to a different type of mask.
Sources for this answer
AirFit F20 or AirFit F40: what are the differences to consider before choosing?
Key takeaway
The F20 covers the nose and mouth; the F40 sits under the nose and around the mouth. Compare contact areas, sizing, seal and precautions: the F40 is not automatically the right choice for everyone.
More detail
Both are full face masks, but their contact areas differ. The AirFit F20 covers the nose and mouth; its cushion rests on the bridge of the nose. The AirFit F40 rests beneath the nose and around the mouth, with a soft silicone cushion. This design may interest people who experience discomfort on the bridge of the nose or wish to read while wearing their glasses.
The F40 is not an upgrade that automatically suits everyone. Compare the seal in your sleeping position, the sizes specific to each model and the precautions concerning magnets. The parts are not interchangeable. For an AirMini, do not assume that the F20’s compatibility also applies to the F40.
Can I use my usual size when switching to another CPAP mask?
Key takeaway
A medium size is not universal. Identify the exact model, then use its manufacturer sizing template at the correct scale; check the cushion size, headgear size and kit contents separately.
More detail
Not automatically. Sizes and shapes vary between ranges; an ‘M’ in one model does not guarantee an ‘M’ in another. The cushion size and headgear size may also correspond to two different product references.
Identify the mask’s full name and use its sizing template or the manufacturer’s guide. If the document needs printing, keep the scale specified. Also compare what is included: a complete mask, a cushion only or a kit containing several sizes. If unsure, ask for advice before breaking the product’s seal, as trying it at home may affect your return options.
Sources for this answer
Which mask should I consider if I sleep on my side or move a lot?
Key takeaway
For side sleeping or frequent movement, look for a mask that stays stable in your actual sleeping position. A compact design or top connection may help, but fit and tube positioning still matter.
More detail
The key factor is how stable the mask remains in your sleeping position. A less bulky model may reduce contact with the pillow; a connection at the top of the head may make some movements easier. These features are useful comparison points, but do not by themselves guarantee a leak-free seal.
Check the tubing position and try the mask while lying down, with the device running as instructed. The pillow must not push the cushion out of position or obstruct the exhalation vents. If you turn frequently in bed, tell your equipment provider before choosing a new interface or support accessory.
Sources for this answer
My mouth is dry with a nasal mask: should I switch to a full face mask?
Key takeaway
A dry mouth alone does not mean you need a full-face mask. First have leaks, nasal breathing, fit and humidification checked; a full-face interface may be considered if mouth leaks persist.
More detail
A dry mouth may suggest that your mouth is opening and leaking air, but it can also have other causes. Before changing masks, have the fit, nasal breathing, recorded leaks and any humidification checked. Dryness alone does not identify the problem.
A full face mask may be appropriate when mouth leaks persist, following an assessment with your equipment provider. A chin strap is not a universal answer, and taping the mouth closed should not be improvised. If your nose remains blocked or discomfort worsens, medical advice can help identify the cause and avoid repeated unsuitable purchases.
Sources for this answer
Can I keep my beard when using a CPAP mask?
Key takeaway
A beard can be compatible with CPAP, but it may affect the seal. Compare contact areas and have the fit checked; no mask suits every beard or every breathing pattern.
More detail
Yes, but facial hair can affect the cushion’s contact and seal. The result depends on hair length, the contact area and the mask’s shape. There is therefore no single model that suits every beard.
Compare the contact areas and have the fit checked before changing to a different type of mask. A nasal interface or a different cushion may be considered if it suits your breathing and treatment. Avoid adding beard oil or cream beneath the cushion to ‘seal’ a leak: greasy residue may instead interfere with the seal and cleaning.
Sources for this answer
Compatibility and safety
Air is escaping from my mask: is it an abnormal leak or normal operation?
Key takeaway
Airflow from the exhalation vents may be normal; a leak against the face, towards the eyes or at a connection needs checking. Check assembly and cushion condition before tightening the straps further.
More detail
CPAP masks generally have a vent designed to release exhaled air. This airflow is normal and its openings must remain clear. A leak against the face, towards the eyes or at a connection can, however, affect comfort and treatment.
Reposition the mask according to its instructions, then check assembly, the cushion’s condition and the tubing connection. Tightening further is not always the answer: it can distort the cushion. Note where the air escapes and which position triggers the leak. If it persists, ask for a check rather than blocking an opening or changing the pressure.
Sources for this answer
Are all masks and tubes compatible with every CPAP device?
Key takeaway
Check the complete setup, not just the mask name. AirMini requires dedicated connections; the F20, N20 and P10 AirMini packs are not interchangeable, and the correct HumidX version depends on the setup.
Compatibility must cover the complete combination of device, tubing, connector, mask and humidification. AirMini uses a dedicated system: a standard connection or a similar mask name is not enough. The following products are available on PlanèteSommeil; compare them with your exact setup before ordering.
| Model | Connector or pack | Check before ordering |
|---|---|---|
| AirFit F20 / AirTouch F20 | Pack F20 38825 | Mask not included; HumidX F20 differs from the nasal versions. |
| AirFit N20 | Pack N20 38823 | Mask not included; check the compatible setup and HumidX. |
| AirFit P10 for AirMini | AirMini P10 mask pack 38824 | Dedicated AirMini version; do not confuse it with the standard P10. |
| AirFit F40 | Not compatible with AirMini according to ResMed | Do not improvise an adapter; ask the manufacturer to confirm before buying. |
HumidX, HumidX Plus and HumidX F20 are not universal. Check the version specified for your mask and the exact pack contents. Manufacturer information checked on 23 November 2026; if a new product reference appears, ask for confirmation before buying.
Are magnetic mask clips suitable for everyone?
Key takeaway
Mask magnets may be contraindicated with certain implants or medical devices, for the wearer or someone nearby. Check the instructions for the exact model and discuss your circumstances before buying.
No. Some masks contain magnets that can interfere with sensitive implants or medical devices. Precautions apply to the wearer and also to certain people nearby during sleep or assistance. Read the contraindications and safety distances specified for the exact model.
Before buying, tell your healthcare professional about any implanted device or medical equipment that might be affected. Do not rely on the clip’s appearance. If there is a contraindication, ask for a mask without magnets that is compatible with your treatment. Check the product information and instructions for the commercial name and magnetic or non-magnetic variants.
Sources for this answer
Do I need to replace the entire mask when a cushion or headgear is worn?
Key takeaway
A worn cushion or headgear does not always mean replacing the whole mask. Check the part, reference and condition; if a homecare provider follows your treatment, first ask what replacement arrangements apply.
More detail
Not always. Depending on the range, the cushion, headgear or certain connectors can be replaced separately. Check compatibility with the model and, where necessary, its version. A similar-looking part does not guarantee correct assembly.
Regularly check for cracks, tears, cushion distortion, loss of elasticity or unusual leaks. Replacement depends on the actual condition, manufacturer instructions and your care arrangements; one schedule does not suit everyone. If your equipment is supplied through a home healthcare provider, contact them first to check the replacement arrangements before buying a duplicate from the shop.
Sources for this answer
Cleaning and protecting your equipment
How should I clean my mask, and do I need an ozone or UV cleaner?
Key takeaway
Clean each component according to its instructions: silicone and foam may need different methods. Warm water, a mild product, rinsing and drying are often specified; wipes do not replace every step.
More detail
Follow the model’s instructions: silicone parts are often washed in lukewarm water with a mild product, then rinsed and dried. Some foam cushions require a different method and must not be immersed. Wipes therefore do not always replace the prescribed cleaning process.
An ozone or UV device is not needed to follow these instructions. These technologies can pose risks and damage certain components; they do not replace the cleaning recommended by the manufacturer. Do not use harsh disinfectants, fragrances or household mixtures across the equipment unless its instructions explicitly permit them.
Sources for this answer
Which water should I use in the humidifier? Can I add essential oils?
Key takeaway
Use only the water permitted by your machine and chamber instructions. Follow the maximum fill level, emptying and cleaning instructions; water intended for ironing is not automatically suitable for respiratory use.
Refer to the instructions for your device and water chamber: the permitted type of water can vary. Use only the water specified, respect the maximum level and follow the emptying and cleaning instructions. Water intended for ironing is not automatically suitable for respiratory use.
Do not add essential oils, fragrances, medicines or disinfectants to the chamber. A CPAP humidifier is not a diffuser. If the air feels too dry or condensation appears in the tubing, ask how to adjust the permitted comfort settings. Changing the water or adding a product will not resolve a mouth leak.
Sources for this answer
Can I wash my CPAP filter and reuse it?
Key takeaway
Disposable AirSense 11 and AirMini filters must not be washed. For any other filter, check its exact instructions; inspect its condition and replace it as specified, sooner if damaged or blocked.
More detail
Only if the instructions for that filter allow it. The disposable air filters in AirSense 11 and AirMini must not be washed or reused after washing. Wetting them to make them look clean again can affect their function. Do not follow maintenance instructions intended for an older device or a different product reference.
Inspect the filter and replace it as instructed by the manufacturer, sooner if damaged or blocked. Check the product reference before ordering and keep the intended cover in place. Do not stack several filters to increase filtration. You can also check the replacement arrangements with your home healthcare provider before making an additional purchase.
Sources for this answer
Inspiration: Antadir/Bash patient book 2010–2011, printed pages 139. This older guide was used to identify practical needs; current manufacturer instructions and recommendations take precedence for equipment guidance. Sources checked: 23 November 2026.
How should I dry and store the equipment before putting it back in its bag?
Key takeaway
Let washable parts dry as instructed before storing them. Avoid heat and direct sunlight, empty the chamber before transport, and protect connections from knocks, pulling and toiletries that could leak.
More detail
After rinsing, allow washable components to air dry away from direct sunlight or heat, following their instructions. Avoid placing a mask or tubing that is still damp inside the bag. The electrical device and its power supply are cleaned separately and must not be immersed in water.
Before transport, empty the humidifier chamber and pack the parts to prevent knocks and strain on the connectors. Keep clean parts away from toiletries that could leak. When reassembling, check that nothing is damaged and that all connections are correctly fitted again.
Sources for this answer
Inspiration: Antadir/Bash patient book 2010–2011, printed pages 139 and 184–186. This older guide was used to identify practical needs; current manufacturer instructions and recommendations take precedence for equipment guidance. Sources checked: 23 November 2026.
How should I clean the CPAP device casing and power supply without damaging them?
Key takeaway
Unplug the CPAP machine before cleaning its exterior. The unit and power supply must not be washed like a mask; for AirSense 11 and AirMini, follow the dry-cloth wiping specified in their instructions.
Switch off and unplug the device before any work. The casing, power supply and power cord are not washed like the mask or water chamber: do not immerse them or pour water into the openings. For AirSense 11 and AirMini, the instructions include wiping the exterior with a dry cloth.
Check the cables and avoid unauthorised fragranced or harsh products. Make sure everything is dry before reconnecting. If liquid has entered the device, it has been dropped or its operation changes, ask your provider how to proceed before using it again. Do not open the casing to clean or repair it.
Sources for this answer
- ResMed: AirSense 11 instructions, Western Europe version
- ResMed: AirMini instructions, European version
Inspiration: Antadir/Bash patient book 2010–2011, printed pages 139. This older guide was used to identify practical needs; current manufacturer instructions and recommendations take precedence for equipment guidance. Sources checked: 23 November 2026.
Should HumidX be washed, and is its lifespan counted in nights of use?
Key takeaway
HumidX must not be washed. HumidX, HumidX Plus and HumidX F20 must be replaced within 30 days of opening the sealed packaging, even when they are not used every night.
More detail
No. HumidX, HumidX Plus and HumidX F20 are waterless humidification systems that must not be washed or immersed. ResMed requires replacement within 30 days of opening the sealed packaging: this does not mean 30 nights spread over several months. Note the date as soon as you open it.
Inspect the component according to its instructions and replace it sooner if damaged or blocked. When not in use, keep it clean and dry; remove it before cleaning other washable parts. Also check the version suited to your mask, as HumidX F20 and the versions intended for nasal setups are not universal.
Sources for this answer
Inspiration: Antadir/Bash patient book 2010–2011, printed pages 139 and 184–187. This older guide was used to identify practical needs; current manufacturer instructions and recommendations take precedence for equipment guidance. Sources checked: 23 November 2026.
Travelling with and powering your CPAP
What should I check before taking my CPAP on a trip or flight?
Key takeaway
Prepare the complete setup, power supply, essential parts and useful documents. Check electrical compatibility and airline rules when flying; test any battery setup before departure rather than discovering a problem away from home.
More detail
Pack the device, power supply, tubing and mask, together with the references for essential spare parts. Check the accepted voltage, plug type and accessories that are actually compatible. Battery runtime depends in particular on the settings and on the use of humidification or heated tubing.
Contact the airline before departure to check its conditions for transport and use in flight, as well as its battery rules. Keep useful documents and your equipment provider’s contact details within reach. A travel CPAP is still a treatment device: its settings and setup must be consistent with your prescription.
Sources for this answer
Which documents should I prepare when flying with my CPAP?
Key takeaway
Carry your prescription, a letter confirming treatment is needed, machine details and provider contacts. Keep an offline copy and confirm cabin carriage, in-flight use and battery requirements with the airline.
More detail
Keep a copy of your prescription, a letter confirming the need for treatment, the device details and your provider’s contact information within reach. For a ResMed device, the manufacturer’s air travel compliance letter may also be useful. Keep these documents with your equipment, ideally with a copy available offline.
Contact the airline well in advance to check its conditions: cabin transport, use during the flight, available power and batteries. Carrying a CPAP does not automatically mean you can use it on board. Confirm the formalities applicable to your journey; do not assume free baggage or any exemption.
Sources for this answer
Inspiration: Antadir/Bash patient book 2010–2011, printed pages 184–187. This older guide was used to identify practical needs; current manufacturer instructions and recommendations take precedence for equipment guidance. Sources checked: 23 November 2026.
Does flight mode stop treatment or only data transmission?
Key takeaway
On supported machines, flight mode disables wireless communications; it does not change the prescribed pressure. Treatment can continue according to the instructions, even when data is not immediately transmitted to the app or provider.
On devices with this feature, flight mode disables wireless communication; it is not used to change the prescribed pressure. A correctly powered and installed device can continue delivering treatment according to its instructions. On AirMini, in-flight use requires Bluetooth to be switched off and the device’s button to be used, as specified by the manufacturer.
Transmission to your provider or the app may therefore be temporarily unavailable. Tell your care team before an extended stay so they can interpret the missing data correctly. On your return, reconnect as instructed. A night that is not immediately displayed in the app does not, by itself, prove that treatment did not work.
Sources for this answer
Inspiration: Antadir/Bash patient book 2010–2011, printed pages 184–187. This older guide was used to identify practical needs; current manufacturer instructions and recommendations take precedence for equipment guidance. Sources checked: 23 November 2026.
How should I choose a battery for CPAP use when camping or without mains power?
Key takeaway
Choose a battery for your exact machine model, with the cable and converter validated as a complete setup. Have runtime estimated for your settings and accessories, then test operation and recharging before departure.
More detail
Have the complete combination of device, battery, cable and converter approved for your exact model. A connector that appears compatible is not enough, and a battery intended for an older range may not suit a recent CPAP. Air10, Air11 and AirMini product references are not interchangeable by default.
Ask for a runtime estimate that matches your settings and intended use of humidification or heated tubing, then test the setup before departure. Plan charging and a backup solution if runtime is insufficient. For air travel, check the airline’s battery rules separately. Do not connect an improvised power supply or adapter.
Sources for this answer
Inspiration: Antadir/Bash patient book 2010–2011, printed pages 118–119 and 184–186. This older guide was used to identify practical needs; current manufacturer instructions and recommendations take precedence for equipment guidance. Sources checked: 23 November 2026.
Is a simple plug adapter enough to connect my CPAP abroad?
Key takeaway
A plug adapter changes the connection shape, not necessarily the voltage. Check your power supply label, the destination supply and compatible cords; do not apply another machine model’s electrical specifications to yours.
More detail
An adapter changes the plug shape; it does not necessarily convert the voltage. Read the label on the power supply supplied with your CPAP and check the electrical supply at your destination. For example, the AirSense 11 power supply described in its instructions accepts an input of 100 to 240 V, but this specification must not be applied to every device.
Use the recommended compatible cord and power supply. Powering the device from a vehicle battery requires a suitable converter, which serves a different purpose from a wall plug adapter. If unsure, give your provider the full model name and your destination before buying an accessory.
Sources for this answer
- ResMed: AirSense 11 instructions, Western Europe version
- ResMed: power supply and accessory compatibility
Inspiration: Antadir/Bash patient book 2010–2011, printed pages 118–119 and 184–187. This older guide was used to identify practical needs; current manufacturer instructions and recommendations take precedence for equipment guidance. Sources checked: 23 November 2026.
Can I leave water in the humidifier when using my CPAP on a flight?
Key takeaway
For AirSense 11 use on an aircraft or in a vehicle, the instructions require an empty water chamber to avoid leaks and water inhalation. Prepare the appropriate setup before departure with your provider and airline.
Do not transfer your bedside setup directly to a flight. For AirSense 11, the manufacturer requires an empty chamber during use in an aircraft or vehicle because movement can cause leaks and water inhalation. The empty chamber or appropriate side cover must remain fitted according to the instructions for your setup.
Plan this use with your provider and the airline, particularly if humidification is important to your comfort. AirMini can use waterless HumidX humidification with a compatible setup; this system cannot be added to just any CPAP. Always empty the chamber before transporting the device.
Sources for this answer
Inspiration: Antadir/Bash patient book 2010–2011, printed pages 184–187. This older guide was used to identify practical needs; current manufacturer instructions and recommendations take precedence for equipment guidance. Sources checked: 23 November 2026.
Published by PlanèteSommeil, a Valeosanté brand. Answers documented using institutional sources, manufacturer instructions and the shop’s current policies. Editorial review: .
The health information presented here does not replace a consultation, diagnosis or your prescriber’s instructions. Links to Valeosanté provide more detail on selected topics and the care pathway.
Try a simpler term or clear the search to see all questions. Our team can also help you find the right information.
Contact usThis information does not replace a consultation or a prescription. Always refer to the instructions and precautions for your equipment or supplement.